resetActive (ro) text state with the active reset input (if control is in reset).3 = app has temporarily disabled control.2 = reset input in config asserted, control is shut down.0 = running, normal operation, waiting for emergency button press.status (ro) the ID of the current status.Provided by AAL Smart Emergency Button control. Setting it to 0 will reenable the Smart Alarm disable (wo) Disable control for a certain period of time, no alarms will be executed.disableEndTime (ro) End time for the control to be disabled.isLeaveActive (ro) Leave input is set, no alarms will be executed.isLocked (ro) Reset active, inputs will be ignored and therefore no alarms will be executed.alarmCause (ro) A string representing the last cause for an alarm.alarmLevel (ro) the ID of the current alarm level.(wo): write-only: this state's value isn't reported by this adapter, but it can be changed, triggering some action on the Loxone Miniserver.(ro): read-only: this state can't be changed from ioBroker.(rw): readable and writable: this state can be changed from ioBroker.The following control types are currently supported by this adapter.īehind the name of the state, you can see the type of the state: all other global states are simply reported as texts.modifications: the number of modifications.notifications: the number of notifications.sunset: the number of minutes after midnight when the sun goes down today.sunrise: the number of minutes after midnight when the sun rises today.operatingMode-text: the current operating mode of the Loxone Miniserver as text.operatingMode: the current operating mode number of the Loxone Miniserver.The following global states are currently provided by this adapter: battery status of Air devices), please verify that the device has "Display diagnostic inputs" checked: To ensure, all your states are properly reported to ioBroker, please verify that they have "Use" in the "User Interface" section checked: That means, they are also hidden from this ioBroker adapter. This is because a user may choose the same name for multiple controls.įor more information about controls and their states, please also have a look at the Loxone API (especially the Structure File): Control Visibilityīy default Loxone Miniserver hides many controls (and thus their states) from the Web interface. The name provided when configuring a control in Loxone Config will only be used as its display name in ioBroker.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |